hose burst valve / hose guard G 3/8" (Notranji navoj)
Št. Izdelka:
SBS 38
Vzorčni prikaz
Opis artikla
Function:
The excess flow cutoff valve allows the quantity of air that is required for smooth operation of compressed air tools to pass through unhindered. However, if the flow increases suddenly, as is typical for a hose fracture or tear, the excess flow cutoff immediately throttles the feed line to the compressed air pipe. Upon replacement of the hose, the excess flow cutoff opens automatically. The hose can thus be prevented from lashing or whipping about. The recommended location for the excess flow cutoff valve is at the joint between the fixed pipeline and the flexible pressure hose, for example, after a maintenance unit.
Materials:
Body: aluminium, piston: POM/aluminium, seal: NBR
Temperature range:
-20°C to max. +80°C (G-3/4" - G 2" to max. +120°C)
Operating pressure:
0 do 18 bar
Media:
oiled and unoiled compressed air
Lastnosti
Iz­ved­ba No­tra­nji navoj
Navoj 1 G 3/8"
Navoj 2 G 3/8" (IG)
Maks. pre­tok (8 bara) 1080
B 58
SW 27
Tem­pe­ra­tur­no ob­mo­čje od -20 do +80
Dodatne informacije:
Teža 65 g / Kos
GTIN 4050571611170
Številka carinskega blaga 84818099
Risba:
Risba: Hose rupture protection, inside / inside
Risba: flow values G 1/4" - G 3/4"
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Nemčija
Vse navedbe podatkov so nezavezujoče orientacijske vrednosti! Za izbiro podatkov, za katere ne izdamo pisnega potrdila, ne prevzemamo jamstev. Navedbe tlaka, v kolikor ni navedeno drugače, se nanašajo na tekočine skupine II. pri +20°C.
Stanje: 03.06.2025