Item group

Liquid level switches - level switches) - combination, level (2x) & temperature (1x)

Exemplary representation: Level switch (fill level switch), combination

Application:

pressure-less applications in hydraulics, mechanical engineering, plant engineering and tank construction. Both the switching positions and their function (NO/NC) can be easily matched in a wireless manner. The switches get actuated upon passing the respective switching position from the bottom to the top, and switch back when the float once again passes the switching position from the top toward the bottom. If so desired, the switch is also available with an additional temperature switch.

Materials:

Body: polyamide, sliding pipe: brass, float: hard PUR, seal: cork

Temperature range:

-20°C to +80°C

Operating pressure:

max. 1 bar

Installation position:

vertical

Protection class:

IP 65

Fixing on the tank cover:

Flange for venting filter DIN 24557-2 (pitch circle 73, hole 60, 6x M 5)

Float dimensions:

Ø 44 x 36 mm

Electrical connection:

Angled plug DIN 43650 / EN 175301-803 A, (plug size 3, 4-pole), (Option with temperature switching contact: angled plug DIN 43651 / EN 175201-804 (6-pole + PE))

Switch type:

Level: 2x NO or NC contacts, bistable*, temperature: 1x NC

Switching capacity:

Level: 30 V (DC), 10 W, max. 0.5 A / Temperature: 30 V (DC), 100 W, max. 2.5 A / Temperature:

Switch-back difference (hysteresis) of the temperature switch:

7 - 13 K

Media:

Water, hydraulic oil, machine oil, diesel and other fluids

Advantages:

•Switching positions L1 and L2 can be changed by changing the level contacts in the 10 mm grid on the contact strip on the inside of the sliding tube,
•Flange fits the flange pattern standardised for hydraulic tanks for ventilation filters (DIN 24557-2),
•Temperature switch allows switching off the machine if the temperature exceeds +70°C,
•Also suitable for slow-flowing media
*by turning the contacts on the switch bar, you can change the contacts from NO to NC contacts.

{{ $t('shop.all.dokumente') }}:

  • Catalogue page Atlas 9 (Page 695b) atlas9_seiten/695b.pdf
    Documentation doku/fullstandsanzeige.pdf
{{ $t('shop.display.artikelgruppe.mehr_informationen') }} {{ $t('shop.display.artikelgruppe.weniger_informationen') }}

{{ $t('shop.display.artikelgruppe.filtern') }}

{{ filter.Eigenschaft.EigenschaftName }}
{{ $t('shop.display.artikelgruppe.kein_eintrag') }}
Liquid level switches - level switches) - combination, level (2x) & temperature (1x):
{{ $t('shop.all.artikelgruppe_n_von_m_artikeln', { anzahlArtikelAngezeigt: anzahlArtikelAngezeigt, anzahlArtikelGesamt: anzahlArtikelGesamt} ) }}
{{ $t('shop.all.unverbindliche_richtwerte') }}
Payment options:
{{ $t('shop.all.spaetbestellservice') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.

  • {{ $t(error) }}