Data sheet

VYKB-F10-M22C-16-PE-5HPA (8122801) Solenoid valve
{{ $t('shop.all.artikelnummer') }}:
OT-FESTO094064
Example illustration
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Construction set up Wippenventil mit Membrandichtung
Sealing principle Soft
From medium contacting materials PEEK
Valve function 2/2 closed monostable
Flow direction Not reversible
Actuation type Electrical
Control type Direct
Reset mode Mechanical spring
Hand assist actuation none
installation position arbitrary
Fastening type mit Durchgangsbohrung für Schraube M2
Electrical connection 1, connection type Cable with plug
Electrical connection 1, connection technology Anschlussbild HP
size 10
Fluid connection flange
medium Gasförmige Medien
Note on the medium maximale Partikelgröße 5 µm
Internal volume 35 µl
Permitted voltage oscillations -0,5
Coil characteristic value 12 V DC: Niederstromphase 1 W, Hochstromphase 3,7 W
Power-on time 100%
Symbol 997351
Housing material PEEK
Diaphragm material EPDM
Seals material EPDM
Werkstoff-Hinweis RoHs compliant
LABS (PWIS) conformity VDMA24364-Zone III
Protection category IP40
Corrosion resistant class KBK 0 - No corrosion stressing
CE certificate (see declaration of conformity) nach EU-RoHS-Richtlinie
UKCA marking (see declaration of conformity) nach UK RoHS Vorschriften
Nominal width [mm] 1,6
Medium temperature [°C] 0 to 50
Medium temperature liquid media [°C] 0 to 50
ambient temperature [°C] 0 to 50
Bearing temperature [°C] -20 to 70
Medium pressure [MPa] -0,075 bis 0,1
Overload pressure [MPa] 0,3
Operating voltage range DC [V] 12
Max. switching frequency [Hz] 2
Shifting time on [ms] 15
Shifting time off [ms] 15
Flow Kv [] 0,034
Product weight [g] 18
Further information:
{{ $t('shop.all.gewicht') }} 18 g / pcs
{{ $t('shop.all.gtin') }} 4052568556662
{{ $t('shop.display.artikel.zollwarennummer') }} 84818087
{{ $t('shop.all.hersteller') }} Festo
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 17.08.2026