Item group

Insertion resistance thermometer, DIN EN IEC 60751

Application:

For general use in mechanical engineering, compressors, refrigeration, heating, air conditioning and ventilation technology, furnace and apparatus construction. Is mainly used for temperature measurement in gases or on the surfaces of solids. When used together with a protective tube, the insertion thermometer can also be used in liquid media.

Materials:

Housing and measured material contacting parts: 1.4571

Temperature range:

-50°C up to max. +200°C (high-temperature version: -10°C to max. +350°C)

Measurement range:

-50°C up to max. +200°C (high-temperature version: -10°C to max. +350°C)

Protection class:

IP 67 (High temperature version: IP 54)

Sleeve diameter

6 mm

Measuring element:

1 x Pt100 (3-wire) or 1 x Pt1000 (2-wire), class F 0.3 (class B) in accordance with DIN EN IEC 60751

Electrical connection:

3 MTR cable, 0.22 mm², silicone-sheathed (high-temperature version: sheathed with glass-fibre stainless steel mesh)

Documents:

More information Less information

Filter items

Izvedba
Please select
Merilni element
Please select
L (dolžina tulca)
Please select
Temperaturno območje
Please select
more filters
Insertion resistance thermometer, DIN EN IEC 60751:
8 of 8 articles
Immediately available
Immediately available
Immediately available
Immediately available
Immediately available
deliverable again in ⌀ 8 weeks
Immediately available
Immediately available
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Payment options:

Cash on delivery

Invoice

Weekend shipping
left 161 min

Simply order on the weekend by Sunday at 15:00 h (or if Monday is a public holiday, by Monday at 15:00 h) and you will receive your merchandise within Germany via GLS on the next working day by 12:00 h (charge: 5%, min. € 30,00).