SFAW-100-X-E-PNLK-PNVBA-M12 (8036889) flow sensor

Número de artículo:

OT-FESTO060520

393,41 € incl. IVA
Udad
Propiedades
Permission RCM mark,
c UL us - Listed (OL)
CE certificate (see declaration of conformity) acc. to EU-EMV Directive,
acc. to EU-RoHS Directive
KC-mark KC-EMV
Material information RoHs compliant
Measured parameter flow,
temperature
Flow direction P1 -> P2,
Uni-directional
Measurement process temperature: PT1000,
Flow: Vortex
Flow measurement range starting value [l/min] 5,0
Flow measurement range end value [l/min] 100
Operating pressure [bar] 0 to 12
Information about operating pressure max. 12 bar at 40°C,
max. 6 bar at 100°C
Operating medium Fluid media,
Neutral liquids,
Water
Information about operating and control medium Media compatibility to the media contacting materials must be guaranteed
Medium temperature [°C] 0 to 90
ambient temperature [°C] 0 to 50
Nominal temperature [°C] 23
Accuracy flow value ±2 %FS for flow <= 50 %FS,
± 3 % o.m.v. for flow >= 50 %FS
Accuracy temperature in ± °C [°C] 2
Repeatability flow value < ±0.5 %FS for flow <= 50 %FS,
< ±1 % o.m.v. for flow >= 50 %FS
Temperature coefficient clamp in ± %FS/K type ±0,05%FS/K
Control output 2 x PNP or 2 x NPN switchable
Switch function Window comparator,
Threshold comparator,
Freely programmable
Switching element function Opener/closer switchable
Max. output current [mA] 100
Analogue output 0 - 10 V,
4 - 20 mA,
1 - 5 V
Flow characteristic curve starting value [l/min] 0
Flow characteristic curve end value [l/min] 100
Max. load resistance current output [Ohm] 500
Min. load resistance voltage output [kOhm] 15
Short circuit resistance yes
Overload resistant Available
Report IO-Link
IO-Link, report Device V 1.1
IO-Link, profile Smart sensor profile
IO-Link, function classes Teach channel,
Diagnosis,
Identification,
Binary data channel (BDC),
Process data variables (PDV)
IO-Link, communication mode COM2 (38.4 kBaud)
IO-Link, SIO mode support yes
IO-Link, port type A
IO-Link, process data width OUT 0 Bytes
IO-Link, process data width IN 3 Bytes
IO-Link, process data contents IN 1 bit BDC (Volume monitoring),
14 bit PDV (Flow measurement),
2 bit BDC (Flow monitoring)
IO-Link, service data unit IN 32 bit Volumenmesswert
IO-Link, minimum cycle time 5 ms
IO-Link, data memory needed [Byte] 500
Operating voltage range DC [V] 18 to 30
Reverse polarity protection for all electrical connections
Electrical connection M12x1,
5 pin,
Plug straight,
A-coded
Max. line length 30 m,
20 m For OK link operation
installation position arbitrary
Fluid connection Customer-site connection
Housing material PA reinforced
From medium contacting materials EPDM (perox.),
ETFE,
stainless steel,
PA6T/6I reinforced
Presentable unit(s) US gal,
US gal/min,
cft,
cft/min,
l,
l/h,
l/min,
m3,
°C,
°F
Protection category IP65
Corrosion resistant class KBK 3 - severe corrosion stress
Más información sobre OT-FESTO060520
Peso 410 g / Udad
GTIN 4052568285432
Código aduanero 90261021
Fabricante Festo
documentos

 
¡Todas las indicaciones se entienden como valores de referencia no vinculantes! No asumimos ninguna responsabilidad por la elección de datos no confirmada por escrito. Las indicaciones de presión se refieren, salvo indicación en contrario, a líquidos del grupo II a +20°C
No en stock
Medios de pago:

Apellido