CMMT-AS-C2-3A-PN-S1 (5340814) servo drive

Artikelnummer:

OT-FESTO082507

€ 1.257,24 incl. btw
Stk
Eigenschappen
Fas­te­ning type As­sem­bly plate, scre­wed
in­stal­la­ti­on po­si­ti­on Open con­vec­ti­on,
ver­ti­cal
Dis­play LED green / yel­low / red
Ope­ra­ting ele­ment Op­ti­o­nal: Con­trol unit CDSB
Com­p­lies to standard EN 61800-​3,
EN 61800-​5-1,
EN 61800-​5-2,
EN ISO 13849-​1
Based on standard EN 50581,
EN 60204-​1,
EN 61508-​1,
EN 61508-​2,
EN 61508-​3,
EN 61508-​4,
EN 61508-​5,
EN 61508-​6,
EN 61508-​7,
EN 61800-​2,
EN 62061
Per­mis­si­on RCM Mark,
TÜV,
c UL us - Li­sted (OL)
KC-​mark KC-​EMV
CE cer­ti­fi­ca­te (see de­cla­ra­ti­on of con­for­mi­ty) acc. to EU-​EMV Di­rec­ti­ve,
acc. to EU Ma­chi­ne Di­rec­ti­ve,
acc. to EU Low vol­ta­ge Di­rec­ti­ve,
acc. to EU-​RoHS Di­rec­ti­ve
Cer­ti­fied awar­ding point UL E331130,
TÜV Rhein­land 01/205/5640.00/18
Be­a­ring tem­pe­ra­tu­re [°C] -25 to 55
am­bient tem­pe­ra­tu­re [°C] 0 to 50
In­for­ma­ti­on about am­bient tem­pe­ra­tu­re Ober­halb der Um­ge­bungs­tem­pe­ra­tur von 40 °C ist eine Leistungs­re­duk­ti­on von 3 %/°C ein­zu­hal­ten.
UL - am­bient tem­pe­ra­tu­re [°C] 0 to 40
Re­la­ti­ve hu­mi­di­ty 5 - 90 %,
Not con­den­sing
Max. setup height [MTR] 2.000
In­for­ma­ti­on about max. setup height From 1000 m power re­duc­ti­on by 1% per 100 m
Pro­tec­ti­on ca­te­go­ry IP20
Pro­tec­ti­on class I
Over-​voltage ca­te­go­ry III
De­gree of con­ta­mi­na­ti­on 2
Surge vol­ta­ge strength [kV] 6
Ma­te­ri­al in­for­ma­ti­on LABS con­tai­ning ma­te­ri­als in­clu­ded,
RoHs com­pli­ant
Phase no­mi­nal ope­ra­ting vol­ta­ge 1-​phase
No­mi­nal ope­ra­ting vol­ta­ge AC [V] 230
Per­mit­ted vol­ta­ge os­cil­la­ti­ons -20 % / +15 %
Input vol­ta­ge range AC [V] 100 to 230
Net­work fre­quen­cy [Hz] 48 to 62
No­mi­nal cur­rent load sup­ply [A] 2,8
Peak cur­rent load sup­ply [A] 8,4
Ac­ti­ve PFC no
Net­work fil­ter in­te­gra­ted
Sy­s­tem vol­ta­ge acc. to EN 61800-​5-1 [V] 300
Max. short cir­cuit re­sis­tan­ce of the net­work [kA] 100
Net­work forms TT,
TN,
IT
No­mi­nal vol­ta­ge load sup­ply DC [V] 320
Per­mit­ted range load sup­ply -20 %/+15 %
Max. in­ter­me­di­a­te cir­cuit vol­ta­ge DC [V] 395
Bra­king re­sis­tan­ce, in­te­gra­ted [Ohm] 100
Im­pul­se power bra­king re­sis­tan­ce [kVA] 1,6
Bra­king re­sis­tan­ce pulse ener­gy [Ws] 230
Bra­king re­sis­tan­ce no­mi­nal per­for­man­ce (IEC) [W] 23
Bra­king re­sis­tan­ce, ex­ter­nal [Ohm] 100 to 160
Max. con­ti­nuous power of the ex­ter­nal bra­king re­sis­tan­ce (IEC) [W] 180
No­mi­nal vol­ta­ge logic sup­ply DC [V] 24
Per­mit­ted range logic vol­ta­ge ± 20 %
Power input logic sup­ply wit­hout par­king brake [A] 0,5
Power input logic sup­ply with par­king brake [A] 1,5
Max. power input for logic sup­ply, par­king brake and IO [A] 2,3
Out­put vol­ta­ge range AC 3x (0 – Input) V
No­mi­nal cur­rent per phase, ef­fec­ti­ve [A] 2
Peak cur­rent per phase, ef­fec­ti­ve [A] 6
Max. peak cur­rent du­ra­ti­on [s] 2
No­mi­nal per­for­man­ce con­trol­ler [VA] 350
Peak per­for­man­ce [VA] 1.000
Out­put fre­quen­cy [Hz] 0 to 599
Max. length motor line wit­hout ext. net­work fil­ter [MTR] 25
Max. out­put cur­rent hol­ding brake [A] 1
Max. vol­ta­ge drop from logic sup­ply to brake out­put [V] 0,8
Quan­ti­ty of in­puts for motor tem­pe­ra­tu­re sen­sor 1
Ope­ra­ting mode con­trol­ler Au­to­tu­ning,
P po­si­ti­on con­trol­ler,
PI-​speed con­trol­ler,
Setup mode,
In­ter­po­la­ted ope­ra­ti­on via field­bus,
Cas­ca­de con­trol,
PI cur­rent con­trol­ler for F or M,
Pro­fi­le ope­ra­ti­on with set and di­rect ope­ra­ti­on,
Re­fe­ren­ce run,
Syn­chro­nous ope­ra­ting modes
Ope­ra­ting mode 2x Input-​Capture (x, v, F),
2x Output-​Trigger (x, v, F),
1x SYNC-​interface for en­co­der emu­la­ti­on or en­co­der input,
2x po­si­ti­on sen­sor input,
Sam­pling rate 16 kHz,
Real time data re­cor­ding,
Field orien­ted con­trol,
Po­si­ti­on re­so­lu­ti­on 24 bit/rev,
PWM with 8 or 16 KHz,
Vec­tor mo­du­la­ti­on with 3rd har­mo­nic
Ether­net in­ter­fa­ce, func­ti­on Pa­ra­me­te­ri­sing and com­mis­si­o­ning
Ether­net in­ter­fa­ce, re­port TCP/IP
Field­bus in­ter­fa­ce, re­port PRO­FI­NET IRT,
PRO­FI­NET RT
Field­bus cou­pling PRO­FI­NET
Com­mu­ni­ca­ti­on pro­fi­le PRO­FIdri­ve,
PRO­FI­ener­gy
Pro­cess cou­pling AC1: Adj.-​Speed Dri­ves,
AC4: Syn­chr. Servo Ap­pli­ca­ti­on,
AC3: Drive w. Po­si­ti­o­ning Func
Field­bus in­ter­fa­ce, trans­fer rate 100 Mbit/s
Field­bus in­ter­fa­ce, con­nec­ti­on type 2x so­c­ket
Field­bus in­ter­fa­ce, con­nec­ti­on tech­no­lo­gy RJ45
En­co­der in­ter­fa­ce, func­ti­on ENDAT 2.1 sen­sor,
ENDAT 2.2 sen­sor,
Hi­per­fa­ce sen­sor,
In­cre­men­tal sen­sor,
Nikon,
SIN/COS sen­sor
En­co­der in­ter­fa­ce 2, func­ti­on In­cre­men­tal sen­sor,
SIN/COS sen­sor
Syn­chro­nous in­ter­fa­ce, func­ti­on Zä­hl­sig­na­le CW/CCW,
Encoder-​Eingang A/B/Z,
En­co­de­r­e­mu­la­ti­on A/B/Z,
Puls-​Richtungssignale CLK/DIR
En­co­der out­put in­ter­fa­ce, pro­per­ties max. 16384 ppr,
1 MHz maxi­ma­le Aus­gangs­fre­quenz
En­co­der input in­ter­fa­ce, pro­per­ties max. 16384 ppr,
1 MHz maxi­ma­le Aus­gangs­fre­quenz
Quan­ti­ty di­gi­tal logic in­puts 12
Swit­ching logic in­puts PNP (Po­si­ti­ve swit­ching)
Pro­per­ties logic in­puts par­ti­al­ly freely con­fi­gu­ra­ble,
not gal­vani­cally se­pa­ra­ted,
par­ti­al­ly sa­fe­ty in­puts
Logic input spe­ci­fi­ca­ti­on de­pen­ding on IEC 61131-​2, type 3
Work area logic input [V] -3 bis 30
Quan­ti­ty of high-​speed logic in­puts 2
Time re­so­lu­ti­on of high-​speed logic in­puts [µs] 1
Quan­ti­ty di­gi­tal logic out­puts 24 V DC 6
Swit­ching logic out­puts PNP (Po­si­ti­ve swit­ching)
Pro­per­ties di­gi­tal logic out­puts par­ti­al­ly freely con­fi­gu­ra­ble,
not gal­vani­cally se­pa­ra­ted,
par­ti­al­ly dia­gno­sis out­puts
Max. cur­rent di­gi­tal logic out­puts [mA] 20
Quan­ti­ty of high-​speed switch out­puts 2
Time re­so­lu­ti­on of high-​speed switch out­puts [µs] 1
Quan­ti­ty of zero po­ten­ti­al switch out­puts 1
Max. cur­rent of the zero po­ten­ti­al switch out­puts [mA] 50
Quan­ti­ty ana­lo­gue tar­get value in­puts 1
Pro­per­ties tar­get value in­puts Dif­fe­ren­ti­al in­puts,
Con­fi­gu­ra­ble for ro­ta­ti­o­nal speed,
Con­fi­gu­ra­ble for cur­rent/force
Work area tar­get value input ± 10 V
Work area ana­lo­gue in­puts ± 10 V
Im­pe­dan­ce tar­get value input [kOhm] 70
Sa­fe­ty func­ti­on Safe swit­ched off tor­que (STO),
Safe bra­king con­trols (SBC),
Safe stop 1 (SS1)
Weight Safe swit­ched off tor­que (STO) / SIL 3 / SILCL 3,
Safe bra­king con­trols (SBC) / SIL 3 / SILCL 3
Per­for­man­ce Level (PL) Safe swit­ched off tor­que (STO) / Ca­te­go­ry 4, Per­for­man­ce Level e,
Safe bra­king con­trols (SBC) / Ca­te­go­ry 3, Per­for­man­ce Level e
Dia­gno­se de­gree of co­ver­a­ge [%] 97
SFF Safe Fai­lu­re Frac­ti­on [%] 99
Hard­wa­re error to­le­ran­ce 1
Quan­ti­ty of safe 2-pin in­puts 2
Quan­ti­ty of dia­gno­sis out­puts 2
Meer informatie over OT-FESTO082507
Gewicht 1,7 kg / Stk
GTIN 4052568597290
Nummer douanegoederen 85044085
Fabrikant Festo
Documenten

 
Alle opgaven zijn bedoeld als niet-bindende richtwaarden! Voor niet schriftelijk bevestigde gegevensselectie zijn wij niet aansprakelijk. Drukgegevens hebben, voor zover niet anders vermeld, betrekking op vloeistoffen uit groep II bij +20 °C.
Direct leverbaar
Betalingsmogelijkheden:

Achternaam

Factuur