Permission |
RCM mark, c UL us - Listed (OL)
|
CE certificate (see declaration of conformity) |
acc. to EU-EMV Directive, acc. to EU-RoHS Directive
|
KC-mark |
KC-EMV
|
Certified awarding point |
UL E322346
|
Material information |
RoHs compliant
|
Measured parameter |
Mass flow, Volume flow rate
|
Flow direction |
Uni-directional
|
Measurement principle |
Thermic
|
Measurement process |
Heat Transfer
|
Flow measurement range starting value [l/min] |
4,000
|
Flow measurement range end value [l/min] |
200,0
|
Operating pressure [bar] |
-0.9 to 10
|
Operating medium |
Druckluft nach ISO 8573-1:2010 [6:4:4], Stickstoff, Argon
|
Medium temperature [°C] |
0 to 50
|
ambient temperature [°C] |
0 to 50
|
Nominal temperature [°C] |
23
|
Accuracy flow value |
± (2% o.m.v. + 1% FS)
|
Repeatability null point in ± %FS [%FS] |
0,2
|
Repeatability clamp in ± %FS [%FS] |
0,8
|
Temperature coefficient clamp in ± %FS/K |
type 0,15%FS/K
|
Pressure dependency clamp in ± %FS/bar [%FS/b.] |
1
|
Control output |
2 x PNP or 2 x NPN switchable
|
Switch function |
Window comparator, Threshold comparator, Auto difference monitoring
|
Switching element function |
Opener/closer switchable
|
Max. output current [mA] |
100
|
Analogue output |
0 - 10 V, 4 - 20 mA, 1 - 5 V
|
Flow characteristic curve starting value [l/min] |
0
|
Flow characteristic curve end value [l/min] |
200,0
|
Max. load resistance current output [Ohm] |
500
|
Min. load resistance voltage output [kOhm] |
20
|
Short circuit resistance |
yes
|
Overload resistant |
Available
|
Report |
IO-Link
|
IO-Link, report |
Device V 1.1
|
IO-Link, profile |
Smart sensor profile
|
IO-Link, function classes |
Teach channel, Diagnosis, Identification, Binary data channel (BDC), Process data variables (PDV)
|
IO-Link, communication mode |
COM2 (38.4 kBaud)
|
IO-Link, SIO mode support |
yes
|
IO-Link, port type |
A
|
IO-Link, process data width IN |
3 Bytes
|
IO-Link, process data contents IN |
1 bit BDC (Volume monitoring), 14 bit PDV (Flow measurement), 2 bit BDC (Flow monitoring)
|
IO-Link, service data unit IN |
32 bit Volumen-/Massemesswert
|
IO-Link, minimum cycle time |
4 ms
|
IO-Link, data memory needed [Byte] |
< 0,5 kB
|
Operating voltage range DC [V] |
22 to 26
|
Empty run current [mA] |
<= 25 mA
|
Reverse polarity protection |
for all electrical connections
|
Electrical connection 1, connection type |
Plug
|
Electrical connection 1, connection technology |
Wiring diagram L1J
|
Electrical connection 1, number of pins / wires |
4
|
Fastening type |
With Accessories
|
installation position |
arbitrary
|
Pneumatic connection |
For hose exterior diameter 8 mm
|
Pneumatic connection, connection outlet |
straight
|
Housing material |
PA reinforced
|
From medium contacting materials |
NBR, high-alloyed stainless steel, PA reinforced, Alu wrought alloy, anodised, Epoxy resin, Silicon, Silicon nitride
|
Display type |
Illuminating LCD Multiple
|
Presentable unit(s) |
g, g/min, l, l/min, scft, scft/h, scft/min
|
Setting options |
IO-Link, Teach-In, über Display und Tasten
|
Tamper-proof fuse |
IO-Link, PIN code
|
Protection category |
IP40
|
Pressure drop [mbar] |
56
|
Protection class |
III
|
Corrosion resistant class KBK |
2 - moderate corrosion stress
|