| Design | round | 
 | Complies to standard | EN 60947-5-2 | 
 | Permission | RCM mark, c UL us - Listed (OL)
 | 
 | CE certificate (see declaration of conformity) | to EU EMC directive, to EU low voltage directive
 | 
 | Material information | Copper and PTFE-free | 
 | Measurement principle | Inductive | 
 | Measurement switching distance [mm] | 5 | 
 | Secured safety distance [mm] | 4,05 | 
 | Reduction factors | aluminium = 0,4, stainless steel St 18/8 = 0,7,
 Copper = 0.3,
 brass = 0,4,
 Steel pc. 37 = 1.0
 | 
 | ambient temperature [°C] | -25 to 85 | 
 | Repeatability [mm] | 0,15 | 
 | Control output | Contactless 2-wire | 
 | Switching element function | NC contact | 
 | Hysteresis [mm] | 0.04 to 1.15 | 
 | Max. switching frequency DC [Hz] | 490 | 
 | Max. switching frequency AC [Hz] | 25 | 
 | Max. output current [mA] | 300 | 
 | Voltage drop [V] | <= 8 V | 
 | Minimum load current [mA] | 5 | 
 | Short circuit resistance | no | 
 | Operating voltage range AC [V] | 20 to 265 | 
 | Operating voltage range DC [V] | 20 to 320 | 
 | Network frequency [Hz] | 50 | 
 | Empty run current [mA] | <= 1,5 mA | 
 | Reverse polarity protection | for all electrical connections | 
 | Electrical connection | 2-wire, cable
 | 
 | size | M18 | 
 | Fastening type | With locking nut | 
 | Torque [Nm] | 30 | 
 | Integration type | flush | 
 | Housing material | PA, brass,
 nickel-plated
 | 
 | Switching status indicator | LED yellow | 
 | Protection category | IP67 | 
 | Corrosion resistant class KBK | 1 - low corrosion stress | 
 | Cable length [MTR] | 2,5 | 
 | Cable sleeve material | TPE-U(PUR) | 
 | Insulation sleeve material | PVC | 
 | Ambient temperature for moving cable placements [°C] | -5 to 50 |