Design |
Angular
|
Based on standard |
VDI/VDE 3845 (NAMUR)
|
Permission |
RCM mark, c UL us - Recognized (OL)
|
CE certificate (see declaration of conformity) |
to EU EMC directive, to EU EX protection directive (ATEX)
|
Material information |
RoHs compliant
|
Measured parameter |
Angle of rotation
|
Measurement principle |
Hall magnetic
|
ambient temperature [°C] |
-20 to 80
|
Analogue output |
4 - 20 mA
|
Repeatability analogue output in ± ° [deg] |
1
|
Short circuit resistance |
yes
|
Overload resistant |
Available
|
Operating voltage range DC [V] |
15 to 30
|
Empty run current [mA] |
12 to 20
|
Reverse polarity protection |
for all electrical connections
|
Electrical connection |
9 pin, Screw clamp, Pluggable
|
Lockable conductor nominal cross-section [mm²] |
2,5
|
Cable screwing |
M20
|
Permitted cable diameter [mm] |
5 to 13
|
Max. line length |
30 m
|
installation position |
arbitrary
|
Housing material |
Aluminium wrought alloy
|
position indicator |
Red / green
|
Setting options |
Teach-in, teach-in via electrical connection
|
Settings range angle recording [deg] |
0 to 270
|
Protection category |
IP65
|
Insulation voltage [V] |
50
|
Surge voltage strength [kV] |
0,8
|
Protection class |
III
|
Corrosion resistant class KBK |
3 - severe corrosion stress
|
Degree of contamination |
3
|
ATEX gas category |
II 3G
|
Ex ignition protection type gas |
Ex nA IIC T5 X Gc
|
ATEX dust category |
II 3D
|
Ex ignition protection type dust |
Ex tc IIIC T90°C X Dc IP65
|
Ex protection approval outside of the EU |
EPL Dc (RU), EPL Gc (RU)
|
Ex ambient temperature |
-20°C <= Ta <= +80°C
|